| 
				   | 
				
| (175 intermediate revisions by the same user not shown) | 
| Line 1: | 
Line 1: | 
 | <div class="nonumtoc">__TOC__</div>
  |  | ==This is demo code demoing math==  | 
 | {{ombox
  |  | 
 | | type      = notice
  |  | 
 | | style     = width: 960px;
  |  | 
 | | text      = This is sublevel2 of my sandbox, where I play with features and test MediaWiki code. If you wish to leave a comment for me, please see [[User_talk:Shawndouglas|my discussion page]] instead.<p></p>
  |  | 
 | }}
  |  | 
 | 
  |  | 
  | 
 | ==Sandbox begins below==
  |  | As a typical example, from a [[calibration plot]] following a [[linear equation]] taken here as the simplest possible model:   | 
 | 
  |  | 
  | 
 | ==AB Sciex Pte. Ltd.==  |  | : <math>f(x) = ax + b </math>  | 
 | '''Main landing page for cannabis testing''': https://sciex.com/applications/food-and-beverage-testing/cannabis-testing
  |  | 
 | 
  |  | 
  | 
 | Commonly known as Sciex, AB Sciex Pte. Ltd. develops "solutions in mass spectrometry paired with capillary electrophoresis and liquid chromatography."<ref name="SciexAbout">{{cite web |url=https://sciex.com/about-us |title=About Us |publisher=AB Sciex Pte. Ltd |accessdate=20 November 2018}}</ref> The company markets some of its solutions for cannabis lab testing, including<ref name="SciexCanna">{{cite web |url=https://sciex.com/applications/food-and-beverage-testing/cannabis-testing |title=Grow Your Cannabis Lab's Potential and Bottom Line with LC-MS/MS Analysis |publisher=AB Sciex Pte. Ltd |accessdate=20 November 2018}}</ref>:
  |  | where, <math>f(x)</math> corresponds to the signal measured (e.g. voltage, luminescence, energy, etc.)  | 
 |    |  | 
 | * pesticide testing
  |  | 
 | * potency testing
  |  | 
 | * mycotoxin testing
  |  | 
 | * terpenes testing
  |  | 
 |    |  | 
 | ===Instruments===
  |  | 
 | ====Triple Quad systems====
  |  | 
 | Sciex offers four different Triple Quad systems for LC-MS/MS: the 6500+, 5500, 4500, and 3500. 
  |  | 
 |    |  | 
 | '''6500+'''
  |  | 
 |    |  | 
 | The [https://sciex.com/products/mass-spectrometers/triple-quad-systems/triple-quad-6500plus-system 6500+] has the following key features, per the website<ref name="Sciex6500+">{{cite web |url=https://sciex.com/products/mass-spectrometers/triple-quad-systems/triple-quad-6500plus-system |title=SCIEX Triple Quad 6500+ LC-MS/MS System |publisher=AB Sciex Pte. Ltd |accessdate=21 November 2018}}</ref>:
  |  | 
 |    |  | 
 | ''Mass Range'': 5-2000 Da
  |  | 
 |    |  | 
 | ''Features'': IonDrive QJet, HED Detector
  |  | 
 |    |  | 
 | ''Detector Type'': IonDrive High Energy Detector+
  |  | 
 |    |  | 
 | ''Scan Types'': Q1 MS, Q3 MS, Product Ion, Precursor Ion, Neutral Loss or Gain, MRM, EMS, EPI, ER, MS3, MRM3
  |  | 
 |    |  | 
 | ''Ionization Sources/Options'': IonDrive Turbo V; OptiFlow™ Turbo V; TurboIonSpray®; Atmospheric-pressure chemical ionization (APCI); DuoSpray™, and NanoSpray® III, Phytronix LDTD, Advion LESA Clarity, Digital PicoView, NanoSource, SelexION®+
  |  | 
 |    |  | 
 | '''5500'''
  |  | 
 |    |  | 
 | The [https://sciex.com/products/mass-spectrometers/triple-quad-systems/triple-quad-5500-system 5500] has the following key features, per the website<ref name="Sciex5500">{{cite web |url=https://sciex.com/products/mass-spectrometers/triple-quad-systems/triple-quad-5500-system |title=SCIEX Triple Quad 5500 LC-MS/MS System |publisher=AB Sciex Pte. Ltd |accessdate=21 November 2018}}</ref>:
  |  | 
 |    |  | 
 | ''Mass Range'': 5-1250 Da
  |  | 
 |    |  | 
 | ''Features'': Turbo V, Pulse Counting Detector
  |  | 
 |    |  | 
 | ''Detector Type'': AcQuRate Pulse Counting Detector
  |  | 
 |    |  | 
 | ''Scan Types'': Q1 MS, Q3 MS, Product Ion, Precursor Ion, Neutral Loss or Gain, MRM
  |  | 
 |    |  | 
 | ''Ionization Sources'': Turbo V, OptiFlow Turbo V, TurboIonSpray® Atmospheric-pressure chemical ionization (APCI); DuoSpray™, and NanoSpray® III, Phytronix LDTD, Advion LESA Clarity, Digital PicoView, NanoSource, SelexION®
  |  | 
 |    |  | 
 | '''4500'''
  |  | 
 |    |  | 
 | The [https://sciex.com/products/mass-spectrometers/triple-quad-systems/triple-quad-4500-system 4500] has the following key features, per the website<ref name="Sciex4500">{{cite web |url=https://sciex.com/products/mass-spectrometers/triple-quad-systems/triple-quad-4500-system |title=SCIEX Triple Quad 5500 LC-MS/MS System |publisher=AB Sciex Pte. Ltd |accessdate=21 November 2018}}</ref>:
  |  | 
 |    |  | 
 | ''Mass Range'': 5-2000 Da
  |  | 
 |    |  | 
 | ''Detector Type'': AcQuRate Pulse Counting Detector
  |  | 
 |    |  | 
 | ''Scan Types'': Q1 MS, Q3 MS, Product Ion, Precursor Ion, Neutral Loss or Gain, MRM
  |  | 
 |    |  | 
 | ''Ionization Sources'': Turbo V; TurboIonSpray; Atmospheric-pressure chemical ionization (APCI); DuoSpray®, and NanoSpray® III
  |  | 
 |    |  | 
 | '''3500'''
  |  | 
 |    |  | 
 | The [https://sciex.com/products/mass-spectrometers/triple-quad-systems/triple-quad-3500-system 3500] has the following key features, per the website<ref name="Sciex3500">{{cite web |url=https://sciex.com/products/mass-spectrometers/triple-quad-systems/triple-quad-3500-system |title=SCIEX Triple Quad 5500 LC-MS/MS System |publisher=AB Sciex Pte. Ltd |accessdate=21 November 2018}}</ref>:
  |  | 
 |    |  | 
 | ''Mass Range'': 5 – 2000 Da
  |  | 
 |    |  | 
 | ''Features'': Turbo V, Pulse Counting Detector
  |  | 
 |    |  | 
 | ''Detector Type'': AcQuRate Pulse Counting Detector
  |  | 
 |    |  | 
 | ''Scan Types'': Q1 MS, Q3 MS, Product Ion, Precursor Ion, Neutral Loss or Gain, MRM
  |  | 
 |    |  | 
 | ''Ionization Sources'': TurboV ion source with TurboIonSpray™ and APCI probes
  |  | 
 |    |  | 
 | ====QTRAP systems====
  |  | 
 | Sciex also offers three different Triple Quad Linear Ion Traps (QTRAP) systems for LC-MS/MS: the 6500+, 5500, and 4500. The company states that these are similar to the Triple Quad systems "but with enhanced scan functions to enable simultaneous quantitation and confirmation."<ref name="SciexQTRAP">{{cite web |url=https://sciex.com/products/mass-spectrometers/qtrap-systems |title=QTRAP LC-MS/MS Systems |publisher=AB Sciex Pte. Ltd |accessdate=21 November 2018}}</ref>
  |  | 
 |    |  | 
 | '''QTRAP 6500+'''
  |  | 
 |    |  | 
 | The [https://sciex.com/products/mass-spectrometers/qtrap-systems/qtrap-6500plus-system QTRAP 6500+] has the following key features, per the website<ref name="SciexQTRAP6500+">{{cite web |url=https://sciex.com/products/mass-spectrometers/qtrap-systems/qtrap-6500plus-system |title=QTRAP 6500+ LC-MS/MS System |publisher=AB Sciex Pte. Ltd |accessdate=21 November 2018}}</ref>:
  |  | 
 |    |  | 
 | ''Mass Range'': Dual switchable mass range: up to 1250 Da or up to 2000 Da
  |  | 
 |    |  | 
 | ''Features'': IonDrive QJet, HED Detector
  |  | 
 |    |  | 
 | ''Detector Type'': IonDrive High Energy Detector+
  |  | 
 |    |  | 
 | ''Scan Types'': Q1 MS, Q3 MS, Product Ion, Precursor Ion, Neutral Loss or Gain, MRM, EMS, EPI, ER, MS3, MRM3, TripleTrap™ Scanning
  |  | 
 |    |  | 
 | ''Ionization Sources/Options'': IonDrive Turbo V; OptiFlow™ Turbo V; TurboIonSpray®; Atmospheric-pressure chemical ionization (APCI); DuoSpray™, and NanoSpray® III, Phytronix LDTD, Advion LESA Clarity, Digital PicoView, NanoSource, SelexION®+
  |  | 
 |    |  | 
 | '''QTRAP 5500'''
  |  | 
 |    |  | 
 | The [https://sciex.com/products/mass-spectrometers/qtrap-systems/qtrap-5500-system QTRAP 5500] has the following key features, per the website<ref name="SciexQTRAP5500">{{cite web |url=https://sciex.com/products/mass-spectrometers/qtrap-systems/qtrap-5500-system |title=QTRAP 5500 LC-MS/MS System |publisher=AB Sciex Pte. Ltd |accessdate=21 November 2018}}</ref>:
  |  | 
 |    |  | 
 | ''Mass Range'': Dual mass range Up to 1250 Da
  |  | 
 |    |  | 
 | ''Features'': Turbo V, Turbo V OptiFlow™, Pulse Counting Detector
  |  | 
 |    |  | 
 | ''Detector Type'': AcQuRate Pulse Counting Detector
  |  | 
 |    |  | 
 | ''Scan Types'': Q1 MS, Q3 MS, Product Ion, Precursor Ion, Neutral Loss or Gain, MRM, EMS, EPI, ER, MS3, MRM3, TripleTrap™ Scanning
  |  | 
 |    |  | 
 | ''Ionization Sources'': Turbo V OptiFlow™, TurboIonSpray Atmospheric-pressure chemical ionization (APCI); DuoSpray™, and NanoSpray® III, Phytronix LDTD, Advion LESA Clarity, Digital PicoView, NanoSource, SelexION®
  |  | 
 |    |  | 
 | '''QTRAP 4500'''
  |  | 
 |    |  | 
 | The [https://sciex.com/products/mass-spectrometers/qtrap-systems/qtrap-4500-system QTRAP 4500] has the following key features, per the website<ref name="SciexQTRAP4500">{{cite web |url=https://sciex.com/products/mass-spectrometers/qtrap-systems/qtrap-4500-system |title=QTRAP 4500 LC-MS/MS System |publisher=AB Sciex Pte. Ltd |accessdate=21 November 2018}}</ref>:
  |  | 
 |    |  | 
 | ''Mass Range'': Up to 2000 Da
  |  | 
 |    |  | 
 | ''Features'': Turbo V, Pulse Counting Detector
  |  | 
 |    |  | 
 | ''Detector Type'': AcQuRate Pulse Counting Detector
  |  | 
 |    |  | 
 | ''Scan Types'': Q1 MS, Q3 MS, Product Ion, Precursor Ion, Neutral Loss or Gain, MRM, EMS, EPI, ER, MS3, MRM3, TripleTrap Scanning
  |  | 
 |    |  | 
 | ''Ionization Sources'': Turbo V; TurboIonSpray; Atmospheric-pressure chemical ionization (APCI); DuoSpray®, and NanoSpray® III, Phytronix LDTD, Advion LESA Clarity, Digital PicoView, NanoSource
  |  | 
 |    |  | 
 | ====vMethod for Cannabis====
  |  | 
 | Sciex also offers a "[https://sciex.com/products/methods/vmethod-application-for-quantitation-of-pesticide-residues-and-cannabinoids-in-cannabis-matrices-10 vMethod]," a quantitation method for pesticide and cannabinoid analysis, that works on many of their LC-MS/MS systems.<ref name="SciexVMethodCann">{{cite web |url=https://sciex.com/products/methods/vmethod-application-for-quantitation-of-pesticide-residues-and-cannabinoids-in-cannabis-matrices-10 |title=vMethod Application for Quantitation of Pesticide Residues and Cannabinoids in Cannabis Matrices 1.0 |publisher=AB Sciex Pte. Ltd |accessdate=21 November 2018}}</ref>
  |  | 
 |    |  | 
 | ==References==
  |  | 
 | {{Reflist|colwidth=30em}}
  |  |