Difference between revisions of "User:Shawndouglas/sandbox/sublevel6"
Shawndouglas (talk | contribs)  | 
				Shawndouglas (talk | contribs)   | 
				||
| Line 19: | Line 19: | ||
===Instruments===  | ===Instruments===  | ||
====Triple Quad systems====  | |||
Sciex offers four different Triple Quad systems for LC-MS/MS: the 6500+, 5500, 4500, and 3500.    | |||
'''6500+'''  | |||
The [https://sciex.com/products/mass-spectrometers/triple-quad-systems/triple-quad-6500plus-system 6500+] has the following key features, per the website<ref name="Sciex6500+">{{cite web |url=https://sciex.com/products/mass-spectrometers/triple-quad-systems/triple-quad-6500plus-system |title=SCIEX Triple Quad 6500+ LC-MS/MS System |publisher=AB Sciex Pte. Ltd |accessdate=21 November 2018}}</ref>:  | The [https://sciex.com/products/mass-spectrometers/triple-quad-systems/triple-quad-6500plus-system 6500+] has the following key features, per the website<ref name="Sciex6500+">{{cite web |url=https://sciex.com/products/mass-spectrometers/triple-quad-systems/triple-quad-6500plus-system |title=SCIEX Triple Quad 6500+ LC-MS/MS System |publisher=AB Sciex Pte. Ltd |accessdate=21 November 2018}}</ref>:  | ||
| Line 34: | Line 36: | ||
''Ionization Sources/Options'': IonDrive Turbo V; OptiFlow™ Turbo V; TurboIonSpray®; Atmospheric-pressure chemical ionization (APCI); DuoSpray™, and NanoSpray® III, Phytronix LDTD, Advion LESA Clarity, Digital PicoView, NanoSource, SelexION®+  | ''Ionization Sources/Options'': IonDrive Turbo V; OptiFlow™ Turbo V; TurboIonSpray®; Atmospheric-pressure chemical ionization (APCI); DuoSpray™, and NanoSpray® III, Phytronix LDTD, Advion LESA Clarity, Digital PicoView, NanoSource, SelexION®+  | ||
'''5500'''  | |||
The [https://sciex.com/products/mass-spectrometers/triple-quad-systems/triple-quad-5500-system 5500] has the following key features, per the website<ref name="Sciex5500">{{cite web |url=https://sciex.com/products/mass-spectrometers/triple-quad-systems/triple-quad-5500-system |title=SCIEX Triple Quad 5500 LC-MS/MS System |publisher=AB Sciex Pte. Ltd |accessdate=21 November 2018}}</ref>:  | The [https://sciex.com/products/mass-spectrometers/triple-quad-systems/triple-quad-5500-system 5500] has the following key features, per the website<ref name="Sciex5500">{{cite web |url=https://sciex.com/products/mass-spectrometers/triple-quad-systems/triple-quad-5500-system |title=SCIEX Triple Quad 5500 LC-MS/MS System |publisher=AB Sciex Pte. Ltd |accessdate=21 November 2018}}</ref>:  | ||
| Line 47: | Line 50: | ||
''Ionization Sources'': Turbo V, OptiFlow Turbo V, TurboIonSpray® Atmospheric-pressure chemical ionization (APCI); DuoSpray™, and NanoSpray® III, Phytronix LDTD, Advion LESA Clarity, Digital PicoView, NanoSource, SelexION®  | ''Ionization Sources'': Turbo V, OptiFlow Turbo V, TurboIonSpray® Atmospheric-pressure chemical ionization (APCI); DuoSpray™, and NanoSpray® III, Phytronix LDTD, Advion LESA Clarity, Digital PicoView, NanoSource, SelexION®  | ||
'''4500'''  | |||
The [https://sciex.com/products/mass-spectrometers/triple-quad-systems/triple-quad-4500-system 4500] has the following key features, per the website<ref name="Sciex4500">{{cite web |url=https://sciex.com/products/mass-spectrometers/triple-quad-systems/triple-quad-4500-system |title=SCIEX Triple Quad 5500 LC-MS/MS System |publisher=AB Sciex Pte. Ltd |accessdate=21 November 2018}}</ref>:  | The [https://sciex.com/products/mass-spectrometers/triple-quad-systems/triple-quad-4500-system 4500] has the following key features, per the website<ref name="Sciex4500">{{cite web |url=https://sciex.com/products/mass-spectrometers/triple-quad-systems/triple-quad-4500-system |title=SCIEX Triple Quad 5500 LC-MS/MS System |publisher=AB Sciex Pte. Ltd |accessdate=21 November 2018}}</ref>:  | ||
| Line 58: | Line 62: | ||
''Ionization Sources'': Turbo V; TurboIonSpray; Atmospheric-pressure chemical ionization (APCI); DuoSpray®, and NanoSpray® III  | ''Ionization Sources'': Turbo V; TurboIonSpray; Atmospheric-pressure chemical ionization (APCI); DuoSpray®, and NanoSpray® III  | ||
'''3500'''  | |||
The [https://sciex.com/products/mass-spectrometers/triple-quad-systems/triple-quad-3500-system 3500] has the following key features, per the website<ref name="Sciex3500">{{cite web |url=https://sciex.com/products/mass-spectrometers/triple-quad-systems/triple-quad-3500-system |title=SCIEX Triple Quad 5500 LC-MS/MS System |publisher=AB Sciex Pte. Ltd |accessdate=21 November 2018}}</ref>:  | The [https://sciex.com/products/mass-spectrometers/triple-quad-systems/triple-quad-3500-system 3500] has the following key features, per the website<ref name="Sciex3500">{{cite web |url=https://sciex.com/products/mass-spectrometers/triple-quad-systems/triple-quad-3500-system |title=SCIEX Triple Quad 5500 LC-MS/MS System |publisher=AB Sciex Pte. Ltd |accessdate=21 November 2018}}</ref>:  | ||
| Line 71: | Line 76: | ||
''Ionization Sources'': TurboV ion source with TurboIonSpray™ and APCI probes  | ''Ionization Sources'': TurboV ion source with TurboIonSpray™ and APCI probes  | ||
----  | ====QTRAP systems====  | ||
Sciex also offers three different Triple Quad Linear Ion Traps (QTRAP) systems for LC-MS/MS: the 6500+, 5500, and 4500. The company states that these are similar to the Triple Quad systems "but with enhanced scan functions to enable simultaneous quantitation and confirmation."<ref name="SciexQTRAP">{{cite web |url=https://sciex.com/products/mass-spectrometers/qtrap-systems |title=QTRAP LC-MS/MS Systems |publisher=AB Sciex Pte. Ltd |accessdate=21 November 2018}}</ref>  | |||
'''QTRAP 6500+'''  | |||
The [https://sciex.com/products/mass-spectrometers/qtrap-systems/qtrap-6500plus-system QTRAP 6500+] has the following key features, per the website<ref name="SciexQTRAP6500+">{{cite web |url=https://sciex.com/products/mass-spectrometers/qtrap-systems/qtrap-6500plus-system |title=QTRAP 6500+ LC-MS/MS System |publisher=AB Sciex Pte. Ltd |accessdate=21 November 2018}}</ref>:  | The [https://sciex.com/products/mass-spectrometers/qtrap-systems/qtrap-6500plus-system QTRAP 6500+] has the following key features, per the website<ref name="SciexQTRAP6500+">{{cite web |url=https://sciex.com/products/mass-spectrometers/qtrap-systems/qtrap-6500plus-system |title=QTRAP 6500+ LC-MS/MS System |publisher=AB Sciex Pte. Ltd |accessdate=21 November 2018}}</ref>:  | ||
| Line 89: | Line 93: | ||
''Ionization Sources/Options'': IonDrive Turbo V; OptiFlow™ Turbo V; TurboIonSpray®; Atmospheric-pressure chemical ionization (APCI); DuoSpray™, and NanoSpray® III, Phytronix LDTD, Advion LESA Clarity, Digital PicoView, NanoSource, SelexION®+  | ''Ionization Sources/Options'': IonDrive Turbo V; OptiFlow™ Turbo V; TurboIonSpray®; Atmospheric-pressure chemical ionization (APCI); DuoSpray™, and NanoSpray® III, Phytronix LDTD, Advion LESA Clarity, Digital PicoView, NanoSource, SelexION®+  | ||
'''QTRAP 5500'''  | |||
The [https://sciex.com/products/mass-spectrometers/qtrap-systems/qtrap-5500-system QTRAP 5500] has the following key features, per the website<ref name="SciexQTRAP5500">{{cite web |url=https://sciex.com/products/mass-spectrometers/qtrap-systems/qtrap-5500-system |title=QTRAP 5500 LC-MS/MS System |publisher=AB Sciex Pte. Ltd |accessdate=21 November 2018}}</ref>:  | The [https://sciex.com/products/mass-spectrometers/qtrap-systems/qtrap-5500-system QTRAP 5500] has the following key features, per the website<ref name="SciexQTRAP5500">{{cite web |url=https://sciex.com/products/mass-spectrometers/qtrap-systems/qtrap-5500-system |title=QTRAP 5500 LC-MS/MS System |publisher=AB Sciex Pte. Ltd |accessdate=21 November 2018}}</ref>:  | ||
| Line 102: | Line 107: | ||
''Ionization Sources'': Turbo V OptiFlow™, TurboIonSpray Atmospheric-pressure chemical ionization (APCI); DuoSpray™, and NanoSpray® III, Phytronix LDTD, Advion LESA Clarity, Digital PicoView, NanoSource, SelexION®  | ''Ionization Sources'': Turbo V OptiFlow™, TurboIonSpray Atmospheric-pressure chemical ionization (APCI); DuoSpray™, and NanoSpray® III, Phytronix LDTD, Advion LESA Clarity, Digital PicoView, NanoSource, SelexION®  | ||
'''QTRAP 4500'''  | |||
The [https://sciex.com/products/mass-spectrometers/qtrap-systems/qtrap-4500-system QTRAP 4500] has the following key features, per the website<ref name="SciexQTRAP4500">{{cite web |url=https://sciex.com/products/mass-spectrometers/qtrap-systems/qtrap-4500-system |title=QTRAP 4500 LC-MS/MS System |publisher=AB Sciex Pte. Ltd |accessdate=21 November 2018}}</ref>:  | The [https://sciex.com/products/mass-spectrometers/qtrap-systems/qtrap-4500-system QTRAP 4500] has the following key features, per the website<ref name="SciexQTRAP4500">{{cite web |url=https://sciex.com/products/mass-spectrometers/qtrap-systems/qtrap-4500-system |title=QTRAP 4500 LC-MS/MS System |publisher=AB Sciex Pte. Ltd |accessdate=21 November 2018}}</ref>:  | ||
| Line 114: | Line 120: | ||
''Ionization Sources'': Turbo V; TurboIonSpray; Atmospheric-pressure chemical ionization (APCI); DuoSpray®, and NanoSpray® III, Phytronix LDTD, Advion LESA Clarity, Digital PicoView, NanoSource  | ''Ionization Sources'': Turbo V; TurboIonSpray; Atmospheric-pressure chemical ionization (APCI); DuoSpray®, and NanoSpray® III, Phytronix LDTD, Advion LESA Clarity, Digital PicoView, NanoSource  | ||
====vMethod for Cannabis====  | |||
Sciex also offers a "[https://sciex.com/products/methods/vmethod-application-for-quantitation-of-pesticide-residues-and-cannabinoids-in-cannabis-matrices-10 vMethod]," a quantitation method for pesticide and cannabinoid analysis, that works on many of their LC-MS/MS systems.<ref name="SciexVMethodCann">{{cite web |url=https://sciex.com/products/methods/vmethod-application-for-quantitation-of-pesticide-residues-and-cannabinoids-in-cannabis-matrices-10 |title=vMethod Application for Quantitation of Pesticide Residues and Cannabinoids in Cannabis Matrices 1.0 |publisher=AB Sciex Pte. Ltd |accessdate=21 November 2018}}</ref>  | |||
==References==  | ==References==  | ||
{{Reflist|colwidth=30em}}  | {{Reflist|colwidth=30em}}  | ||
Revision as of 14:47, 21 November 2018
| 
   | 
This is sublevel2 of my sandbox, where I play with features and test MediaWiki code. If you wish to leave a comment for me, please see my discussion page instead. | 
Sandbox begins below
AB Sciex Pte. Ltd.
Main landing page for cannabis testing: https://sciex.com/applications/food-and-beverage-testing/cannabis-testing
Commonly known as Sciex, AB Sciex Pte. Ltd. develops "solutions in mass spectrometry paired with capillary electrophoresis and liquid chromatography."[1] The company markets some of its solutions for cannabis lab testing, including[2]:
- pesticide testing
 - potency testing
 - mycotoxin testing
 - terpenes testing
 
Instruments
Triple Quad systems
Sciex offers four different Triple Quad systems for LC-MS/MS: the 6500+, 5500, 4500, and 3500.
6500+
The 6500+ has the following key features, per the website[3]:
Mass Range: 5-2000 Da
Features: IonDrive QJet, HED Detector
Detector Type: IonDrive High Energy Detector+
Scan Types: Q1 MS, Q3 MS, Product Ion, Precursor Ion, Neutral Loss or Gain, MRM, EMS, EPI, ER, MS3, MRM3
Ionization Sources/Options: IonDrive Turbo V; OptiFlow™ Turbo V; TurboIonSpray®; Atmospheric-pressure chemical ionization (APCI); DuoSpray™, and NanoSpray® III, Phytronix LDTD, Advion LESA Clarity, Digital PicoView, NanoSource, SelexION®+
5500
The 5500 has the following key features, per the website[4]:
Mass Range: 5-1250 Da
Features: Turbo V, Pulse Counting Detector
Detector Type: AcQuRate Pulse Counting Detector
Scan Types: Q1 MS, Q3 MS, Product Ion, Precursor Ion, Neutral Loss or Gain, MRM
Ionization Sources: Turbo V, OptiFlow Turbo V, TurboIonSpray® Atmospheric-pressure chemical ionization (APCI); DuoSpray™, and NanoSpray® III, Phytronix LDTD, Advion LESA Clarity, Digital PicoView, NanoSource, SelexION®
4500
The 4500 has the following key features, per the website[5]:
Mass Range: 5-2000 Da
Detector Type: AcQuRate Pulse Counting Detector
Scan Types: Q1 MS, Q3 MS, Product Ion, Precursor Ion, Neutral Loss or Gain, MRM
Ionization Sources: Turbo V; TurboIonSpray; Atmospheric-pressure chemical ionization (APCI); DuoSpray®, and NanoSpray® III
3500
The 3500 has the following key features, per the website[6]:
Mass Range: 5 – 2000 Da
Features: Turbo V, Pulse Counting Detector
Detector Type: AcQuRate Pulse Counting Detector
Scan Types: Q1 MS, Q3 MS, Product Ion, Precursor Ion, Neutral Loss or Gain, MRM
Ionization Sources: TurboV ion source with TurboIonSpray™ and APCI probes
QTRAP systems
Sciex also offers three different Triple Quad Linear Ion Traps (QTRAP) systems for LC-MS/MS: the 6500+, 5500, and 4500. The company states that these are similar to the Triple Quad systems "but with enhanced scan functions to enable simultaneous quantitation and confirmation."[7]
QTRAP 6500+
The QTRAP 6500+ has the following key features, per the website[8]:
Mass Range: Dual switchable mass range: up to 1250 Da or up to 2000 Da
Features: IonDrive QJet, HED Detector
Detector Type: IonDrive High Energy Detector+
Scan Types: Q1 MS, Q3 MS, Product Ion, Precursor Ion, Neutral Loss or Gain, MRM, EMS, EPI, ER, MS3, MRM3, TripleTrap™ Scanning
Ionization Sources/Options: IonDrive Turbo V; OptiFlow™ Turbo V; TurboIonSpray®; Atmospheric-pressure chemical ionization (APCI); DuoSpray™, and NanoSpray® III, Phytronix LDTD, Advion LESA Clarity, Digital PicoView, NanoSource, SelexION®+
QTRAP 5500
The QTRAP 5500 has the following key features, per the website[9]:
Mass Range: Dual mass range Up to 1250 Da
Features: Turbo V, Turbo V OptiFlow™, Pulse Counting Detector
Detector Type: AcQuRate Pulse Counting Detector
Scan Types: Q1 MS, Q3 MS, Product Ion, Precursor Ion, Neutral Loss or Gain, MRM, EMS, EPI, ER, MS3, MRM3, TripleTrap™ Scanning
Ionization Sources: Turbo V OptiFlow™, TurboIonSpray Atmospheric-pressure chemical ionization (APCI); DuoSpray™, and NanoSpray® III, Phytronix LDTD, Advion LESA Clarity, Digital PicoView, NanoSource, SelexION®
QTRAP 4500
The QTRAP 4500 has the following key features, per the website[10]:
Mass Range: Up to 2000 Da
Features: Turbo V, Pulse Counting Detector
Detector Type: AcQuRate Pulse Counting Detector
Scan Types: Q1 MS, Q3 MS, Product Ion, Precursor Ion, Neutral Loss or Gain, MRM, EMS, EPI, ER, MS3, MRM3, TripleTrap Scanning
Ionization Sources: Turbo V; TurboIonSpray; Atmospheric-pressure chemical ionization (APCI); DuoSpray®, and NanoSpray® III, Phytronix LDTD, Advion LESA Clarity, Digital PicoView, NanoSource
vMethod for Cannabis
Sciex also offers a "vMethod," a quantitation method for pesticide and cannabinoid analysis, that works on many of their LC-MS/MS systems.[11]
References
- ↑ "About Us". AB Sciex Pte. Ltd. https://sciex.com/about-us. Retrieved 20 November 2018.
 - ↑ "Grow Your Cannabis Lab's Potential and Bottom Line with LC-MS/MS Analysis". AB Sciex Pte. Ltd. https://sciex.com/applications/food-and-beverage-testing/cannabis-testing. Retrieved 20 November 2018.
 - ↑ "SCIEX Triple Quad 6500+ LC-MS/MS System". AB Sciex Pte. Ltd. https://sciex.com/products/mass-spectrometers/triple-quad-systems/triple-quad-6500plus-system. Retrieved 21 November 2018.
 - ↑ "SCIEX Triple Quad 5500 LC-MS/MS System". AB Sciex Pte. Ltd. https://sciex.com/products/mass-spectrometers/triple-quad-systems/triple-quad-5500-system. Retrieved 21 November 2018.
 - ↑ "SCIEX Triple Quad 5500 LC-MS/MS System". AB Sciex Pte. Ltd. https://sciex.com/products/mass-spectrometers/triple-quad-systems/triple-quad-4500-system. Retrieved 21 November 2018.
 - ↑ "SCIEX Triple Quad 5500 LC-MS/MS System". AB Sciex Pte. Ltd. https://sciex.com/products/mass-spectrometers/triple-quad-systems/triple-quad-3500-system. Retrieved 21 November 2018.
 - ↑ "QTRAP LC-MS/MS Systems". AB Sciex Pte. Ltd. https://sciex.com/products/mass-spectrometers/qtrap-systems. Retrieved 21 November 2018.
 - ↑ "QTRAP 6500+ LC-MS/MS System". AB Sciex Pte. Ltd. https://sciex.com/products/mass-spectrometers/qtrap-systems/qtrap-6500plus-system. Retrieved 21 November 2018.
 - ↑ "QTRAP 5500 LC-MS/MS System". AB Sciex Pte. Ltd. https://sciex.com/products/mass-spectrometers/qtrap-systems/qtrap-5500-system. Retrieved 21 November 2018.
 - ↑ "QTRAP 4500 LC-MS/MS System". AB Sciex Pte. Ltd. https://sciex.com/products/mass-spectrometers/qtrap-systems/qtrap-4500-system. Retrieved 21 November 2018.
 - ↑ "vMethod Application for Quantitation of Pesticide Residues and Cannabinoids in Cannabis Matrices 1.0". AB Sciex Pte. Ltd. https://sciex.com/products/methods/vmethod-application-for-quantitation-of-pesticide-residues-and-cannabinoids-in-cannabis-matrices-10. Retrieved 21 November 2018.
 