Difference between revisions of "User:Shawndouglas/sandbox/sublevel8"
Shawndouglas (talk | contribs)  | 
				Shawndouglas (talk | contribs)   | 
				||
| Line 109: | Line 109: | ||
[https://www.law.cornell.edu/cfr/text/42/493.1274 42 CFR Part 493.1274]<br />  | [https://www.law.cornell.edu/cfr/text/42/493.1274 42 CFR Part 493.1274]<br />  | ||
[https://www.law.cornell.edu/cfr/text/42/493.1283 42 CFR Part 493.1283]<br />  | [https://www.law.cornell.edu/cfr/text/42/493.1283 42 CFR Part 493.1283]<br />  | ||
[https://www.aavld.org/accreditation-requirements-page   | [https://www.aavld.org/accreditation-requirements-page AAVLD Requirements for an AVMDL Sec. 5.8.2]<br />  | ||
[http://www.abft.org/files/ABFT_LAP_Standards_May_31_2013.pdf ABFT Accreditation Manual D-3]<br />  | [http://www.abft.org/files/ABFT_LAP_Standards_May_31_2013.pdf ABFT Accreditation Manual D-3]<br />  | ||
[https://www.astm.org/Standards/E1578.htm ASTM E1578-18 C-1-12]<br />  | [https://www.astm.org/Standards/E1578.htm ASTM E1578-18 C-1-12]<br />  | ||
| Line 135: | Line 135: | ||
[http://www.oecd.org/chemicalsafety/testing/oecdseriesonprinciplesofgoodlaboratorypracticeglpandcompliancemonitoring.htm OECD GLP Principles 6.1]  | [http://www.oecd.org/chemicalsafety/testing/oecdseriesonprinciplesofgoodlaboratorypracticeglpandcompliancemonitoring.htm OECD GLP Principles 6.1]  | ||
   | style="background-color:white;" |The system shall provide a user-friendly means for acknowledging the physical reception of sample material in the laboratory, including date and time of reception.  |    | style="background-color:white;" |The system shall provide a user-friendly means for acknowledging the physical reception of sample material in the laboratory, including date and time of reception.  | ||
 |-   | |||
  | style="padding:5px; width:500px;" |[https://www.astm.org/Standards/E1578.htm ASTM E1578-18 C-1-14]<br />[https://www.epa.gov/sites/production/files/documents/erln_lab_requirements.pdf EPA ERLN Laboratory Requirements 4.4.6]  | |||
  | style="background-color:white;" |The system shall allow for the comparison of received samples to the sampling requirements of the customer or laboratory in order to identify variances from those requirements.  | |||
 |-   | |||
  | style="padding:5px; width:500px;" |  | |||
[https://www.aavld.org/accreditation-requirements-page AAVLD Requirements for an AVMDL Sec. 5.8.3]<br />  | |||
[https://www.astm.org/Standards/E1492.htm ASTM E1492-11 4.1.1.5]<br />  | |||
[https://www.astm.org/Standards/E1492.htm ASTM E1492-11 4.1.6]<br />  | |||
[https://www.astm.org/Standards/E1492.htm ASTM E1492-11 4.3.3.2]<br />  | |||
[https://www.astm.org/Standards/E1578.htm ASTM E1578-18 C-1-15]<br />  | |||
[https://www.epa.gov/sites/production/files/documents/erln_lab_requirements.pdf EPA ERLN Laboratory Requirements 4.4.13]<br />  | |||
[https://www.epa.gov/sites/production/files/documents/erln_lab_requirements.pdf EPA ERLN Laboratory Requirements 4.11.8]<br />  | |||
[https://www.ams.usda.gov/datasets/pdp/pdp-standard-operating-procedures USDA Sample Processing and Analysis Procedures for PDP 5.1.3–7]<br />  | |||
[https://www.ams.usda.gov/datasets/pdp/pdp-standard-operating-procedures USDA Sampling Procedures for PDP 6.4.1.1.9]  | |||
  | style="background-color:white;" |The system should provide a means to document any undesirable or unexpected characteristics of a submitted sample.  | |||
  |-    |   |-    | ||
|}  | |}  | ||
|}  | |}  | ||
Revision as of 17:01, 13 September 2019
| 
   | 
This is sublevel1 of my sandbox, where I play with features and test MediaWiki code. If you wish to leave a comment for me, please see my discussion page instead. | 
Sandbox begins below
1. Sample/Experiment Registration
  | ||||||||||||||||||||||||||||||||||||