LabLynx KB:ELab 7 user manual - sample receiving

From LIMSWiki
Jump to navigationJump to search

Sample Receiving Overview

ELab enables you to log in and receive single samples, as opposed to sample groups or orders/projects - although they also may easily be associated with a project or other group/category/entity etc. In the Sample Add/Edit screen users can enter and edit sample information. This can include specific information like collection data, sample point data, disposal data, comments, test assignments and applications.

For a demonstration of Sample Receiving in ELab, see: Camera edited.png Sample Receiving (http://files.mylablynx.com/share/eBooks/Movies/d140/d140.html)


To Add or Edit Samples

Navigate to the Sample Receiving menu item. This will usually be the top menu item if your lab primarily receives samples singly, or else it can be found in the master LabLynx Menu in the LIMS/Receiving folder.

Sample Receiving Menu.png


The Samples List screen displays all samples in the system, with the filter defaulted to show only those samples not yet received.

Note: Samples are color-coded: Yellow = Test(s) Assigned, Green = Under Testing, Grey = Complete.


To log a sample as "Received", the user selects it and clicks the Receive Receive Button.jpg button, whereupon it will drop from the pre-filtered list. See #To Receive Samples below for detailed instructions.

Sample Receive 1.jpg


To view or edit an existing sample, you can filter for the criteria that will display it (i.e. a date range, received/not received, submitter, sample type, etc.). Once it is displayed, simply click the sample number, and ELab displays its Sample Detail screen.

Sample Receiving Detail screen - Gen SS.png


You can add or edit any details for that sample here. When finished, click Save Save Button.jpg and then Done Done button.jpg.


To add a new sample, from the Samples List screen, click New New Button.jpg.

The New Sample Detail screen displays.

New Sample.jpg


You can enter all appropriate information for that sample. A unique sample number will be automatically generated upon saving. Required fields are in bold.


Fields/Descriptions

The following fields may or may not be present, depending on your lab's particular configuration. Some may have been renamed, and others may have been added, but these are the default fields in the COTS (Commercial-Off-The-Shelf) LIMS.

  • Priority - Select a priority from the drop-down picklist.
  • Description - This is a free text field, enter a description of the sample that has meaning for your lab.
  • Location/Department - This defaults to the user's logged-in location, but may be changed initially by clicking it (Note: once saved, it is not editable!).
  • Sample Collection Date - Click the calendar icon to select date, or type it in (01/02/15 or 01/02/2015 format), and enter a time (09:00 format).
  • Material Type - Select the type from the drop-down picklist. Type the first letter(s) of the type in the field to the left for faster selection.
  • Collected By - Select the sampler by clicking the Select link.
  • Lab Due Date - Click the calendar icon to enter any deadline for the sample.
  • Program Type - Select any type of program to be associated with the sample from the drop-down picklist (if this is present).
  • Sample Detail Fields - Miscellaneous attributes or information regarding the sample may be listed in these text fields. The names of the fields may be edited to suit usage (see Label Definitions )
  • Billable - Check this box if the sample is billable.
  • OnHold - Select this checkbox if the sample is to be put on hold for any reason.
  • PO Number - Enter any associated Purchase Order number.
  • Received Date - Date the sample was received. Click the calendar icon to populate the field.


Once the required (bold) fields are filled in, the sample may be saved at any time by clicking Save Save Button.jpg. At this point a unique Sample Number is generated by the system, and additional detail frames are displayed. You may continue to edit. When done, click Save Save Button.jpg. Clicking Done Done button.jpg collapses the additional detail frames; clicking Done Done button.jpg again returns you to the Samples List.


Sample Relationships and Items

In the Sample Detail area users can enter additional details concerning the sample, including the defining of relationships between the sample and any other types of entities in the system. A sample can have one or more relationships associated with it.


For example, the user could choose the relationship type "The sample." This tells the system that the user is going to provide further information about the sample by choosing the Item or entity to associate with the sample. Items are particular sets of characteristics. They can include customer specs or limits, sets of tests, etc. When an Item is associated with a sample, its traits are automatically assigned to the sample. Items are set up in the Item Management menu item in the administrator menu (access is usually restricted to LIMS administrators). See LabLynx KB:ELab 7 user manual - item management


Item Management 860.png

Note the Item Specs or Apply Spec Limits Apply Spec Limits Button.png button, which allows for the assignment of pre-set limit sets or specifications. This is often used when a particular client or sample type, etc. requires a different set of limits than the assigned tests normally flag.


Another example of Item usage would be where the user chooses a relationship type of "Manufacturer." This would tell the system that the user is going to define another entity to associate with the sample besides the Submitter:

LLXLIMS Receiving-38.jpg


Assign Sample Test Run area

The Test Assignment area of the screen allows you to assign/unassign tests, using the unassigned/assigned frame. Any tests that have been automatically assigned will show up in the Assigned frame. Should it be necessary to add or remove test(s), click on the appropriate test(s) and click on the Assign Assign Button.png or Assign All Assign All.png button to add them or the Unassign Unassign Button.png or Unassign All Unassign All Button.png button to remove them:


Assign Tests - Food Lab.png


The user may also add a pre-defined group of tests to the sample, to aid in speedier registration by clicking on the Add Test Group Add Test Group Button.png button and choosing the test group(s) to be added to the sample:


Add Test Group.png


In the Assigned frame, the system displays the test name as a hyperlink. This link takes the user to an edit screen to assign the sample/test to a subcontract laboratory, edit the detection limits for the test parameters for this sample, add a test run for this sample, or cancel the test run:


Assigned Test Detail Screen.png


Sample Detail screen with details

Sample Receiving Detail screen - Gen SS.png

To Receive Samples

From the Sample Receiving Samples List screen (menu item Sample Receiving or as renamed for your lab), check the boxes to the left of any/all samples you wish to receive, and click Receive Receive Button.jpg.

Sample Receive 1.jpg


The system popup asks if you would like to print labels for the selected project(s).


Print Labels.jpg


Select "Yes" to print. The labels are displayed in order as .pdf files. You may print as many labels as needed.


Sample Label - Barcoded2.png


Whether you print labels or not, once Sample Groups have been received they are removed from the Sample Group receiving list screen.


Associated Files

The Associated Files area lists any files you want to associate with the sample. Any file type is supported. Edit an existing record simply by clicking the selected record to display the Add/Edit Associated Files screen. Add a new file by selecting the New New Button.jpg button or the Batch Upload Batch Upload Button S.png button in the Associated Files area, to display the Add/Edit Associated Files dialog:

Upload Associated File 800px 1.png


Select a file and send to server

Upload Associated File 800px 2.png